HVAC
DIF.420
FEATURES
Accuracy 0,5% F.S.
Ranges: from vacuum to 200 bar
Casing fully stainless steel AISI 304
DPT-2W
FEATURES
Accuracy (from FS):±1.5 %
Supply voltage:10…35 VDC
Output signal:4…20 mA
DPT 200
Features
Differential pressure von 1 mbar up to 20 bar
Accuracy: 0.075 % FSO
turn-down max. 100:1
HART®-communication
DPT-R8
FEATURES
Accuracy :Pressure < 125 Pa = 1 % + ±2 Pa
Pressure > 125 Pa = 1 % + ±1 Pa
Measuring units:Pa, kPa, mbar, inchWC, mmWC, psi
ZPU
FEATURES
Accuracy: 1% F.E. (repeatability, hysteresis, linearity)
Tracks: from vacuum to 1000 bar
DPT-Dual-MOD
FEATURES
Communication: RS-485 Modbus (RTU)
Accuracy (from applied pressure):
(model 2500)Pressure < 125 Pa = 1 % + ±2 Pa
Zero point calibration: via Modbus or by pushbutton
DPT-Flow
FEATURES
Accuracy :
Pressure < 125 Pa = 1 % + ±2 Pa
Zero point calibration:automatic with autozero element (-AZ) or by pushbutton
DPT-MOD
FEATURES
Communication:RS-485 Modbus (RTU)
Accuracy :
Pressure < 125 Pa = 1 % + ±2 Pa
pressure > 125 Pa = 1 % + ±1 Pa
Zero point calibration:via Modbus or by pushbutton
AVT
FEATURES
Accuracy: < 0.2 m/s + 5 % (Range 0...2 m/s)...
Measuring units: m/s, °C
Protection standard: IP54
CDT-MOD-2000
FEATURES
Communication:RS-485 Modbus (RTU)
Accuracy: CO2: ±40 ppm + 2 % of reading, DC model: 75 ppm or 10 % of reading (whichever is greater)
S2-400P MICROPROCESS DIGITAL METER
FEATURES
4 digits LED display: 9999
Accuracy : ±0.05% to ±0.25%
Measuring adjustment in input sensing deviation
CDT-MOD-2000 Duct
FEATURES
Communication: RS-485 Modbus (RTU)
Accuracy: CO2: ±40 ppm + 2 % of reading, DC model: 75 ppm or 10 % of reading (whichever is greater)
S2-412PA MICROPROCESS DIGITAL METER RELAY
FEATURES
4 1/2 digits LED display: ±1999
Accuracy : ±0.05% to ±0.25%
Auto-zero and hold function
Measuring adjustment in input sensing deviation
S2-300A 3 DIGITAL METER RELAY
FEATURES
3 digits LED display: ±999
Accuracy : ±0.1% to ±0.25%
Auto-zero and hold function
26.600 G
FEATURES
Nominal pressure: 0 ... 1 bar up to 0 ... 400 bar
Accuracy: 0.5 % FSO
Media: fuels and oils ,gases
S2-400A 4 DIGITAL METER RELAY
FEATURES
4 digits LED display: ±9999
Accuracy : ±0.05% to ±0.15%
Auto-zero and hold function
30.600 G
FEATURES
Nominal pressure: 0 ... 1,6 bar up to 0 ... 250 bar
Accuracy: 1 % FSO
Media: fuels and oils ,gases
S2-800WH/S2-800RH MICROPROCESS WATT(VAR) HOUR METER
FEATURES
8 digits display: 99999999
Accuracy: ±0.3%
Programmable adjustment for current, voltage transformers ratio
Precision measurement even for unbalance system
S2-800WHT/S2-800RHT MICROPROCESS WATT(VAR) HOUR METER
FEATURES
8 digits display: 99999999
Accuracy: ±0.3%
Programmable adjustment for current, voltage transformers ratio
Precision measurement even for unbalance system
Provide a variety of output
S2-800MT MICROPROCESS AC POWER METER
FEATURES
8 digits display: 99999999(WH)
4 digits display: 9999(V,A,W)
Accuracy: ±0.3% F.S. ±1 digit , PF≧0.5
Programmable adjustment for current, voltage transformers ratio
Precision measurement even for unbalance system
SI4 Mini Plug-in Display
FEATURES
Display 4 digit red LED display
Accuracy: ±0.1% F.S.±1digit
IP enclosure IP 65
S3-DT FOUR OUTPUT DC SIGNAL TRANSMITTER
FEATURES
Steady voltage, current and low ripple output.
Three/Four isolated output.
Isolation: Input to output to power.
S4T-DT SIGNAL ISOLATED TRANSMITTER
FEATURES
Converting a DC input into a standard process signal.
Wide input and output range selection.
Isolation: Input to output to power.
S4T-2DT TWO-WIRE ISOLATED TRANSMITTER
FEATURES
Power supply for tow wire output :DC 11~32V
Converting a DC input into a standard process signal.
Isolation: Input to output
S4T-DS LOOP POWERED ISOLATOR
FEATURES
DC 4-20mA/DC 4-20mA, self powered.
Isolation: Input to output, between channels.
S4T-DTD SIGNAL ISOLATED TRANSMITTER (TWO OUTPUT)
FEATURES
Converting a DC input into a standard process signal.
Two isolated output.
4 way isolated.
S4T-DW CURRENT LOOP SUPPLY( ISOLATED )
FEATURES
Powering a 4 ~ 20mA DC current loop.
Output voltage: DC 24V.
Isolation: Input to output to power
S4T-DWD CURRENT LOOP SUPPLY (TWO OUTPUT ISOLATED)
FEATURES
Powering a 4 ~ 20mA DC current loop.
Output voltage: DC 24V.
Two isolated output.
S4T-RR RTD ISOLATED TRANSMITTER
FEATURES
Converting a RTD (Pt100) input into a standard process signal.
Automatically eliminated for wire Resistance
(3 wires connection).
Isolation: Input to output to power
S4T-2RR TWO-WIRE RTD ISOLATED TRANSMITTER
FEATURES
Power supply for tow wire output :DC 11~32V
Converting a RTD (Pt100) input into a standard process signal.
Automatically eliminated for wire Resistance
(3 wires connection).
S4T-TC THERMOCOUPLE ISOLATED TRANSMITTER
FEATURES
Converting a T.C. input into a standard process signal. Cold junction compensated.
Isolation: Input to output to power.
S6-300 Multifunctional Power Meter
FEATURES
User-friendly
Cost effective
Direct access to the measured display
Measurement in 1P/3P3W/3P4W systems
T330 Power Meter
FEATURES
User-friendly
Cost-effective
Quick installation
Light and short depth
Quick setup parameters
Energy-saved protection mode
T250 Power Meter
FEATURES
User-friendly
Cost effective
Output modules on actual demand
Direct access to the measured display
Measurement in 1P/3P3W/3P4W systems